Alpha CFR 15K Instrukcja Operatora

Przeglądaj online lub pobierz Instrukcja Operatora dla Zasilacze Alpha CFR 15K. Alpha CFR 15K Operator`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 54
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
UNITED KINGDOM
Alphatec U.K.
5 The Astra Centre,
Edinburgh Way
Harlow, Essex CM20 2BE
44-279-422110
FAX: 44-279-423355
GERMANY
Alphatechnic
Hansastrasse 8
D-8540 Schwabach
49-9122-997303
FAX: 49-9122-997321
MIDDLE EAST
Alphatec
P.O. Box 6468 #208
Limassol, Cyprus
357-5-375675
FAX: 357-5-359595
CANADA
Alpha Technologies
5700 Sidley Street
Burnaby, B.C. V5J 5E5
(604) 430-1476
FAX: (604) 430-8908
UNITED STATES
Alpha Technologies
3767 Alpha Way
Bellingham, WA 98226
(206) 647-2360
FAX: (206) 671-4936
ALPHA TECHNOLOGIES
ALPHA TECHNOLOGIES
F R O M A L P H A T E C H N O L O G I E S
Information Management
Using the Intelligent
Interface Device
Operator's Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 53 54

Podsumowanie treści

Strona 1 - Operator's Manual

UNITED KINGDOMAlphatec U.K.5 The Astra Centre,Edinburgh WayHarlow, Essex CM20 2BE44-279-422110FAX: 44-279-423355GERMANYAlphatechnicHansastrasse 8D-85

Strona 2

Front Panel IndicatorsIn addition to the LCD display, the Intelligent Interface Device usesbacklit LED's to indicate LINE PRESENT, LINE FAILURE,

Strona 3

Press CLEAR to return to the DEFAULT screen.Press CLEAR to return to the DEFAULT screen.Press CLEAR to return to the DEFAULT screen.Press CLEAR to ret

Strona 4 - Intelligent Interface Device

5. COMMUNICATION INTERFACE OPTIONS 1. INTRODUCTIONRemote Communications Operation1. You can directly access the Intelligent Interface Device by typing

Strona 5 - History Logs

353535353565. COMMUNICATION INTERFACE OPTIONS1. INTRODUCTIONENTERKeyALPHA TECHNOLOGIESALPHA TECHNOLOGIESALPHA TECHNOLOGIESALPHA TECHNOLOGIESALPHA TECH

Strona 6

Front Panel FeaturesThe front panel of the Intelligent Interface Device is designed to be easyto use and extremely flexible to provide you with a wide

Strona 7

RS-232The UPS can be remotely setup, monitored, and tested using a PC'sRS-232 serial port. RS-232 remote operation is accomplished by connecting

Strona 8

UPS Front Panel InstallationThe CFR UPS is designed so that upgrading from a Standard InterfaceDevice to an Intelligent Interface Device is as easy as

Strona 9

3. OPERATION2. INSTALLATION313131313110Press CLEAR to return to ALPHA TECHNOLOGIES default screen;Press CLEAR to return to ALPHA TECHNOLOGIES default

Strona 10

Maintenance Parameters"MAINTENANCE PARAMETERS" allow you to customize UPSdetection and warning characteristics. Normally, there should be n

Strona 11 - Front Panel Screens

Remote InstallationThe Intelligent Interface Device can also be used for remote applicationsaway from the UPS. The distance is dependent upon the gau

Strona 12 - Short cut tip

018-029-B0 9/93©1993 Alpha TechnologiesThe Intelligent Interface DeviceInformation ManagementUsing the IntelligentInterface DeviceOperator's Ma

Strona 13 - Modem Installation (optional)

Event Descriptions, continuedBlackout - A blackout is a complete loss of AC Line power. * *Frequency High - A frequency high is a power line problem

Strona 14 - RS-485 Serial Operation

Event DescriptionsThere are a number of EVENTS that can be detected and recorded inthe EVENT HISTORY log. Some of these conditions can be damaging to

Strona 15 - 9 8 7 6

Front Panel IndicatorsLine Present"LINE PRESENT" indicates that the UPS is running on AC Line power.Whenever a utility outage occurs, the in

Strona 16 - 4. ALARMS

Alpha Technologies (DEFAULT) ScreenThe "ALPHA TECHNOLOGIES" default screen displays date and timeinformation. The default screen is continu

Strona 17

System ParametersThe "SYSTEM PARAMETERS" screen provides UPS efficiency andbattery temperature information. The main menu prompts you to se

Strona 18 - Remove for MODEM

Input Parameters"INPUT PARAMETERS" provides UPS Input Voltage, Current, VoltAmps, Power in Watts, Power Factor, and Line Frequency informati

Strona 19 - 3. OPERATION

3. OPERATION 3. OPERATION191919191922User Parameters"USER PARAMETERS" allows you to set the UPS time and date, enterthe capacity of the batt

Strona 20 - Set Time and Date

2121212121203. OPERATION3. OPERATIONBattery Parameters"BATTERY PARAMETERS" provides UPS Battery Voltage, ChargerCurrent, and Charger Status

Strona 21

2121212121203. OPERATION3. OPERATIONBattery Parameters"BATTERY PARAMETERS" provides UPS Battery Voltage, ChargerCurrent, and Charger Status

Strona 22

3. OPERATION 3. OPERATION191919191922User Parameters"USER PARAMETERS" allows you to set the UPS time and date, enterthe capacity of the batt

Strona 23

018-029-B0 9/93©1993 Alpha TechnologiesThe Intelligent Interface DeviceInformation ManagementUsing the IntelligentInterface DeviceOperator's Ma

Strona 24

Input Parameters"INPUT PARAMETERS" provides UPS Input Voltage, Current, VoltAmps, Power in Watts, Power Factor, and Line Frequency informati

Strona 25

System ParametersThe "SYSTEM PARAMETERS" screen provides UPS efficiency andbattery temperature information. The main menu prompts you to se

Strona 26

Alpha Technologies (DEFAULT) ScreenThe "ALPHA TECHNOLOGIES" default screen displays date and timeinformation. The default screen is continu

Strona 27 - Battery Parameters

Front Panel IndicatorsLine Present"LINE PRESENT" indicates that the UPS is running on AC Line power.Whenever a utility outage occurs, the in

Strona 28

Event DescriptionsThere are a number of EVENTS that can be detected and recorded inthe EVENT HISTORY log. Some of these conditions can be damaging to

Strona 29

Event Descriptions, continuedBlackout - A blackout is a complete loss of AC Line power. * *Frequency High - A frequency high is a power line problem

Strona 30

Remote InstallationThe Intelligent Interface Device can also be used for remote applicationsaway from the UPS. The distance is dependent upon the gau

Strona 31

Maintenance Parameters"MAINTENANCE PARAMETERS" allow you to customize UPSdetection and warning characteristics. Normally, there should be n

Strona 32

3. OPERATION2. INSTALLATION313131313110Press CLEAR to return to ALPHA TECHNOLOGIES default screen;Press CLEAR to return to ALPHA TECHNOLOGIES default

Strona 33

UPS Front Panel InstallationThe CFR UPS is designed so that upgrading from a Standard InterfaceDevice to an Intelligent Interface Device is as easy as

Strona 34

The Intelligent Interface DeviceTable of ContentsTable of ContentsTable of ContentsTable of ContentsTable of Contents Information Management Using the

Strona 35

RS-232The UPS can be remotely setup, monitored, and tested using a PC'sRS-232 serial port. RS-232 remote operation is accomplished by connecting

Strona 36

Front Panel FeaturesThe front panel of the Intelligent Interface Device is designed to be easyto use and extremely flexible to provide you with a wide

Strona 37

353535353565. COMMUNICATION INTERFACE OPTIONS1. INTRODUCTIONENTERKeyALPHA TECHNOLOGIESALPHA TECHNOLOGIESALPHA TECHNOLOGIESALPHA TECHNOLOGIESALPHA TECH

Strona 38

5. COMMUNICATION INTERFACE OPTIONS 1. INTRODUCTIONRemote Communications Operation1. You can directly access the Intelligent Interface Device by typing

Strona 39

Press CLEAR to return to the DEFAULT screen.Press CLEAR to return to the DEFAULT screen.Press CLEAR to return to the DEFAULT screen.Press CLEAR to ret

Strona 40

Front Panel IndicatorsIn addition to the LCD display, the Intelligent Interface Device usesbacklit LED's to indicate LINE PRESENT, LINE FAILURE,

Strona 41

1. INTRODUCTION 7. APPENDIX39393939392SpecificationsOperating Temp 320 -1040 F / 00 - 400CIndicators Line Present, Line Failure,Low Battery Shutdown,L

Strona 42

How To Use This ManualThe manual has been designed to introduce and familiarize you with thevarious features of the Alpha Intelligent Interface Device

Strona 43

7. APPENDIX411. INTRODUCTIONUnpacking and InspectionThe Intelligent Interface Device, standard with the CFR 7.5K, CFR 10K,and CFR 15K, requires no ins

Strona 44

The Intelligent Interface Device42Table of Contents, continued3. OPERATION, continued28Output Voltage LowOutput Voltage HighOutput Power OverloadOutpu

Strona 45

The Intelligent Interface Device 7. APPENDIXIndex, continuedPprompt, input, 6, 8Rremote installation, 12remote operation, 36repair instructions, 38RS-

Strona 46 - Specifications

The Intelligent Interface Device 7. APPENDIXIndex, continuedPprompt, input, 6, 8Rremote installation, 12remote operation, 36repair instructions, 38RS-

Strona 47 - Serial Operation Standards

The Intelligent Interface DeviceTable of ContentsTable of ContentsTable of ContentsTable of ContentsTable of Contents Information Management Using the

Strona 48 - Unpacking and Inspection

The Intelligent Interface DeviceThe Intelligent Interface DeviceThe Intelligent Interface DeviceThe Intelligent Interface DeviceThe Intelligent Interf

Strona 49

The Intelligent Interface DeviceThe Intelligent Interface DeviceThe Intelligent Interface DeviceThe Intelligent Interface DeviceThe Intelligent Interf

Strona 50

© 2000 Alpha Technologies017-139-B0-002 01/00USA, LATIN AMERICA& ASIA PACIFICAlpha Technologies3767 Alpha WayBellingham, WA 98226Tel: (360) 64

Strona 51

The Intelligent Interface Device42Table of Contents, continued3. OPERATION, continued28Output Voltage LowOutput Voltage HighOutput Power OverloadOutpu

Strona 52 - SAVE THESE INSTRUCTIONS

7. APPENDIX411. INTRODUCTIONUnpacking and InspectionThe Intelligent Interface Device, standard with the CFR 7.5K, CFR 10K,and CFR 15K, requires no ins

Strona 53

How To Use This ManualThe manual has been designed to introduce and familiarize you with thevarious features of the Alpha Intelligent Interface Device

Strona 54 - Novus P1250 and 1250T

1. INTRODUCTION 7. APPENDIX39393939392SpecificationsOperating Temp 320 -1040 F / 00 - 400CIndicators Line Present, Line Failure,Low Battery Shutdown,L

Komentarze do niniejszej Instrukcji

Brak uwag